Engineering scenario

Taian · Water transfer across large elevation changes

Use consistent elevations and verify minimum and maximum pressure, working points and protective actions.

Water transfer across large elevation changes
Illustrative scene View full image

Checks and records

Operating conditions
Combine static lift, terminal pressure, pipe and fitting losses, allowing for available inlet pressure.
Site coordination
Plot normal and peak duty on the pump curve. Check operating range, input power and suction conditions.
Commissioning
Record water temperature and inlet pressure. For sewage pumps, add solids, fibres, sump levels and lifting access.